AskCylinder movement abnormal alarm
AnswerAnalysis of the problem 1: The mechanical structure of the guide shaft or other mechanical components is stuck due to foreign matter, causing the cylinder to fail to operate normally. Inspection method: Observe if there is any foreign matter. Solution: Remove any foreign matter. Replace it if it is damaged. Problem Analysis 2: The cylinder operates normally, but the cylinder sensor does not light; Check method: Observe whether the cylinder sensor is off or not. Solution: Loosen the sensor, adjust and tighten the sensor screw, and the cylinder is damaged. Loose, change the cylinder; sensor damage, need to replace the sensor; Problem 3: Circuit contact failure inspection method: check the circuit   Solution: Reconnect
AskCylinder can not normally drive mechanism
AnswerProblem Analysis 1: The pressure value does not reach the specified range, or the throttle valve is tightened tightly; Inspection method: Observe the barometer; Solution: stabilize and adjust the intake air source, the speed control valve can be adjusted normally; Problem Analysis 2: Loosening valve, pipe joints, etc., loose, leak, etc.; Inspection method: Manually check the speed control valve, pipe joints; Solution: If there is damage, replace it, if the lock is bad, then lock the relevant components; Problem Analysis 3: Inhibition of blockage in the movement part of the mechanism Inspection method: Manually push-pull the air-disconnected mechanism to find out; Solution: Clear up the blockage.